Screening System Package (8 cells), System for electrosynthesis, multi-batch, 8
The picture may be different from the article and can include supply, which is not in the standard scope.
Screening System Package (8 cells), System for electrosynthesis, multi-batch, 8 undivided cells
The IKA Screening System is perfectly suited for constant current electrosynthesis in “multibatch” mode. The package with 8 undivided batch cells enables you to quickly carry out research on multiple electroconversions at the same time. In addition, you can combine the system with other equipment in the laboratory.
The usage of the single-cell screening system allows you to customize each reaction cell. The operator is able to individually pre-set an applied voltage of 0 – 32 V or 0 – 10 A current by using two voltage sources, each providing four outputs. Every reaction cell can be equipped with electrodes made of either different or the same electrode material. This depends strongly on the electro synthesis envisioned. All cells are arranged in a heating block that, if necessary, is heated up by a magnetic stirrer belonging to the scope of delivery. An external PT 1000 temperature sensor ensures the monitoring and control of the exact heating block temperature.
- Up to 8 undivided cells can be operated simultaneously and individually
- Synthesize sufficient quantities for GC, LC or NMR analysis processes
- Separate control and pre-set for each cell
- Easy testing of identical or differing electrolysis runs
- Fast identification of ideal process parameters
- Digital recording of test parameters
- Simultaneous mixing and heating
- Full temperature control (PT 1000) using heat block
- Control and automation via Labworldsoft 6.0
- Time and resources savings
more The IKA Screening System is perfectly suited for constant current electrosynthesis in “multibatch” mode. The package with 8 undivided batch cells enables you to quickly carry out research on multiple electroconversions at the same time. In addition, you can combine the system with other equipment in the laboratory.
The usage of the single-cell screening system allows you to customize each reaction cell. The operator is able to individually pre-set an applied voltage of 0 – 32 V or 0 – 10 A current by using two voltage sources, each providing four outputs. Every reaction cell can be equipped with electrodes made of either different or the same electrode material. This depends strongly on the electro synthesis envisioned. All cells are arranged in a heating block that, if necessary, is heated up by a magnetic stirrer belonging to the scope of delivery. An external PT 1000 temperature sensor ensures the monitoring and control of the exact heating block temperature.
- Up to 8 undivided cells can be operated simultaneously and individually
- Synthesize sufficient quantities for GC, LC or NMR analysis processes
- Separate control and pre-set for each cell
- Easy testing of identical or differing electrolysis runs
- Fast identification of ideal process parameters
- Digital recording of test parameters
- Simultaneous mixing and heating
- Full temperature control (PT 1000) using heat block
- Control and automation via Labworldsoft 6.0
- Time and resources savings
| (-) Technical data: | |
|---|---|
| Asepsis: | No |
| EAN Code: | 4053411048853 |
| (-) Compliance information: | |
|---|---|
| WEEE obligation: | Yes |
| WEEE registration number: | DE66784213 |
- Article-No: 0040003642
- Category: electrodes
Show all electrodes from IKA - Index: conductivity sensors, Oxygen probes
- Validity: 31.10.2026
- Last Update: 04.06.2026
Accessories:
- 0020015936
Reaction block 6 cells, Reaction block with 6 divided cells - 0020015943
Reaction block 8 cells, Reaction block with 8 undivided cells - 0020023690
Labworldsoft 6 Screening System, Laboratory software - download - 0020023860
Electrode 0.7 platinum on ceramic, Electrode for Screening System - 0020110119
SC.MF, Manifold - 0020110375
SC.MF.CP.UDIV, Manifold cap, for undevided cells - 0040003646
Electrode Starter Kit, Set incl. 9 different electrodes for Screening System - 0040003648
Undivided cells Set, 8 undivided cells - 0040003669
Electrode 0.7 graphite V2100, Electrode for Screening System - 0040003670
Electrode 0.7 glassy carbon , Electrode for Screening System - 0040003671
Electrode 0.7 nickel, Electrode for Screening System - 0040003672
Electrode 0.7 stainless steel, Electrode for Screening System - 0040003673
Electrode 0.7 lead, Electrode for Screening System - 0040003674
Electrode 0.7 lead bronze, Electrode for Screening System - 0040003675
Electrode 0.7 copper, Electrode for Screening System - 0040003677
Electrode 0.7 magnesium, Electrode for Screening System - 0040003678
Electrode 0.7 platinum , Electrode for Screening System - 0040003680
Electrode 0.7 zinc, Electrode for Screening System - 0040003682
Electrode 0.7 aluminium, Electrode for Screening System - 0040003932
Electrode 0.7 BDD, Electrode for Screening System - 0040003933
Electrode 0.7 cobalt, Electrode for Screening System - 0040003934
Electrode 0.7 gold, Electrode for Screening System - 0040003935
Electrode 0.7 nickel foam, Electrode for Screening System - 0040003936
Electrode 0.7 niobium, Electrode for Screening System - 0040003937
Electrode 0.7 RVC, Electrode for Screening System - 0040003938
Electrode 0.7 silver , Electrode for Screening System - 0040003939
Electrode 0.7 tin, Electrode for Screening System - 0040003940
Electrode 0.7 titanium, Electrode for Screening System - 0040003941
Electrode 0.7 tungsten, Electrode for Screening System - 0040003954
Electrode 0.7 graphite SK-50, Electrode for Screening System - 0040004509
Electrode 0.7 Sampler Kit, Set incl. 7 x 2 different electrodes for Screening Sy