Instrument intensive cleaner
For medical instruments and equipment for ultrasound

At a glance
- Concentrate
- Very high cleaning efficiency
- High blood dissolving capacity
- Removes even stubborn, dried-up
Impurities such as blood, secretions etc.
- For use in the ultrasonic bath
- Very high material compatibility
- Pleasant smell
- Biodegradable

General information
STAMMOPUR R is a formula-optimised,
mild alkaline cleaning concentrate for thorough
Intensive cleaning of medical instruments and
devices in an ultrasonic bath. It enables very short
ultrasonic cleaning times and is therefore particularly gentle on the
sensitive instruments. As contact liquid
recommended for basic cleaning with STAMMOPUR GR
Material compatibility
STAMMOPUR R is suitable for all in medicine
materials used. The instructions of the instrument manufacturers
must be observed. For endoscopes and -to
the suitability recommendations of the companies
Karl-Storz GmbH and Richard Wolf GmbH.
Instructions for use
STAMMOPUR R is supplied as a concentrate and can be
without problems with water of min. drinking water quality
be diluted. The addition of cleaning boosters
and/or disinfectants are not
permissible.

Application
Cleaning in an ultrasonic bath
2 % 3 - 10 minutes
20 - 60 °C
Exposure time depending on the type and
Persistence of pollution
Cleaning without ultrasound
Dosage: 3-5

When used in an ultrasonic device, the
Observe the instructions of the ultrasonic device manufacturer.
Ensure complete wetting of the instrument surfaces
respect. Insert the hollow body so that the air
escapes completely from the cavities.
After cleaning parts thoroughly with water of
min. Drinking water quality or quality according to RKI recommendation
rinse and dry. Instruments on
Check cleanliness and function. Subsequent disinfection,
Final disinfection or sterilisation depending on
Classification of the medical device.
The working solution is not suitable for visible, coarse soiling
immediately, otherwise at the latest every day to
change. The ultrasonic bath after emptying
disinfect to avoid cross-contamination.

Hazard warnings
H318 Causes severe eye damage.

Safety Instructions
P280 Wear protective gloves/protective clothing/eye protection/face protection
P305+P351+P338 IN CONTACT WITH EYES: Rinse gently with water for several minutes.
Remove existing contact lenses if possible. Continue rinsing.
At a glance
-Concentrate
-Very high cleaning efficiency
-High blood solubility
-Removes even stubborn, dried up impurities such as blood, secretions etc.
-For use in an ultrasonic bath
-Very high material compatibility
-Attractive odor
-Biologically degradable

General information
STAMMOPUR R is a formula-optimised, mildly alkaline cleaning concentrate for thorough intensive cleaning of medical instruments and
devices in an ultrasonic bath. It enables very short ultrasonic cleaning times and thus protects particularly sensitive instruments. As contact liquid
recommended for basic cleaning with STAMMOPUR GR

Material compatibility
STAMMOPUR R is suitable for all materials used in medicine. The instructions of the instrument manufacturers
must be observed. For endoscopes and accessories the suitability recommendations of Karl-Storz GmbH and Richard Wolf GmbH are available.

Instructions for use
STAMMOPUR R is supplied as a concentrate and can easily be diluted with water of min. drinking water quality. The additions of cleaning boosters
and/or disinfectants are not permitted.

Application
Cleaning in an ultrasonic bath
2 % 3 - 10 minutes
20 - 60 °C
Application time depending on the type and persistence of the dirt

Danger warnings
H318 Causes severe eye damage.

Safety Instructions
P280 Wear protective gloves/protective clothing/eye protection/face protection
P305+P351+P338 IN CONTACT WITH EYES: Rinse gently with water for several minutes.
Remove existing contact lenses if possible. Continue rinsing.
more
(-) Technical data:
coustic container volume: 2
(-) Security-related data:
GHS Number: GHS05
Signal word: Danger
Hazard statements: H318
Precautionary statements: P280,P305+P351+P338