Compressor-cooled incubator ICP260, 256l, -12-60°C

Compressor-cooled incubator ICP260, 256l, -12-60°C
The picture may be different from the article and can include supply, which is not in the standard scope.
  • (Click here for more information)
  • pdf_preview
  • pdf_preview
 
Order-No.: 102602602 6.685,00 € for 1 piece plus VAT (19%) plus shipping costs
Compressor-cooled incubator ICP260, with TwinDISPLAY, 256 l, working-temperature range and setting range -12 °C to +60 °C (not suitable for long-term storing at sub-zero temperatures. During permanent operation, the glass door may ice over); with 2 grids, outside stainless steel door, inside glass door, electronically adjustable fan speed from 10 % to 100 % in 10 % steps, Ethernet interface for reading out protocol log, uploading programmes and for online logging, USB port on ControlCOCKPIT for use of USB stick, multiple overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +10 °C, +37 °C; textured stainless steel exterior: 824 x 1552 x 684 mm; stainless steel interior: 640 x 800 x 500 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1200 W
more
(-) Technical data:
Product type description: ICP260
Nominal volume: 256 l
Minimum operating temperature: -12 °C
Maximum operating temperature: 60 °C

Accessories:

  • ICP260B29722
    Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribu
  • ICP260B29725
    Perforated stainless steel shelf
  • ICP260B29738
    Flush-fit unit (stainless steel frame covering gap between oven and wall opening
  • ICP260B29739
    Flush-fit unit (stainless steel frame covering gap between oven and wall opening
  • ICP260B33170
    USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (Use
  • ICP260D00124
    IQ document with device-specific works test data, OQ/PQ check list as support fo
  • ICP260D00127
    IQ/OQ document with device-specific works test data for one free-selectable temp
  • ICP260E06189
    Ethernet connection cable 5 m for computer interface
  • ICP260E06192
    USB-Ethernet adapter
  • ICP260E28891
    Stainless steel grid, electropolished
  • ICP260E29726
    Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distri
  • ICP260E29766
    Additional reinforced stainless steel grid, electropolished, max. loading 60 kg;
  • ICP260FDAQ1
    FDA confroming software AtmoCONTROL (FDA edition). Meets the requirements for th
  • ICP260FDAQ2
    Integration of additional units (up to max. 15 units) into an already existent F

 

Options:

  • ICP260B6
    Door with lock (safety lock)
  • ICP260B8
    Door hinged on the left
  • ICP260C3
    MobileALERT, notification by SMS in case of any error or alarm of the device. Re
  • ICP260D00109
    Works calibration certificate for one (freely selectable) temperature value acco
  • ICP260D00130
    Works calibration certificate for 3 temperatures: 0 °C, +37 °C, +60 °C
  • ICP260D4
    Process-dependent programmable door lock
  • ICP260F0
    Entry port, 23 mm clear diameter, for introducing connections at the side, can b
  • ICP260F1
    Entry port, 23 mm clear diameter, for introducing connections at the side, can b
  • ICP260F3
    Entry port, 23 mm clear diameter, for introducing connections at the side, can b
  • ICP260F7
    Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by si
  • ICP260H4
    Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, accordi
  • ICP260H5
    Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for exte
  • ICP260H6
    Potential-free contact for combination error message (e.g. supply failure, senso
  • ICP260H72
    Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal ­ gener
  • ICP260H8
    Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for l
  • ICP260R3
    Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switc
  • ICP260V3
    4 - 20 mA current loop interface 4 - 20 mA current loop interface (-20 to +70 °C
  • ICP260V4
    Fan speed monitoring with switching off the heating and with alarm in case of fa
  • ICP260V5
    Door-open-recognition
  • ICP260V6
    4 - 20 mA current loop interface Temperature of a Pt100 sensor positioned flexib
  • ICP260X2
    Voltage 115 V, 50/60 Hz