Vacuum oven VO49, 49l, 20-200°C, pressure control 5-1100mbar

Vacuum oven VO49, 49l, 20-200°C, pressure control 5-1100mbar
The picture may be different from the article and can include supply, which is not in the standard scope.
  • (Click here for more information)
 
Order-No.: 412660400 8.656,00 € for 1 piece plus VAT (19%) plus shipping costs
Vacuum oven VO49, with TwinDISPLAY, 49 l, working-temperature range at least 5 °C above ambient temperature to +200 °C, setting temperature range 20 °C - 200 °C; digital electronic pressure control from 5 - 1100 mbar, with pump control, optimised rinsing procedures for the pump membranes as well as signal output for pump ON/OFF, with thermoshelf with 2 connectors for thermoshelves in the back, safety glass door with inner bullet-proof glass and external anti-spinter screen; stainless steel door, electronically adjustable air flap from 0 to 100 % in 10 % steps, Ethernet interface for reading out protocol log, uploading programmes and for online logging, USB port on ControlCOCKPIT for use of USB stick, multiple overtemperature protection, internal data logger with storage capacity of at least 10 years, calibration facility; works calibration certificate at +160 °C and 20 mbar pressure; textured stainless steel exterior: 550 x 687 x 480 mm; stainless steel interior: 385 x 385 x 330 mm; voltage: 230 V, 50/60 Hz; max. electrical load: approx. 1020 W
more
(-) Technical data:
Nominal volume: 49 l
Minimum operating temperature: 25 °C
Maximum operating temperature: 200 °C

Accessories:

  • VO49B00734
    Thermoshelf - stainless steel material 1.4404 (ASTM 316 L) for especially corros
  • VO49B00743
    Thermoshelf - aluminium eloxadised material W.-St. 3.3547 (ASTM B209) with integ
  • VO49B04026
    Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connectio
  • VO49B33170
    USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (Use
  • VO49B39410
    Signal cable (3 m) for control of rotation speed and optimising pump performance
  • VO49D00115
    Calibration - three temperature values (at +50 °C, +100 °C, +160 °C at 20 mbar)
  • VO49D00117
    IQ/OQ document incl. empty chamber distribution measurement according to DIN 128
  • VO49D00124
    IQ/OQ/PQ checklist
  • VO49E02031
    Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum
  • VO49E06189
    Ethernet connection cable 5 m for computer interface
  • VO49E06192
    USB-Ethernet adapter
  • VO49E07509
    Vacuum pump with chemically resistant 4x diaphragm, pump capacity at atm. pressu
  • VO49FDAQ1
    Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of el
  • VO49FDAQ2
    Integration of additional units (up to max. 31 units) into an already existent F
  • VO49GA2Q5
    Guarantee extension by 1 year - U: sizes 260 - 1060; UF TS: sizes 260 - 750 ; VO
  • VO49PM49
    Noise-insulated vacuum pump module without pump (exterior dimensions and -materi
  • VO49PMP49
    Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V,

 

Options:

  • VO49C3
    MobileALERT, notification by SMS in case of any error or alarm of the device (re
  • VO49C4
    MobileALERT for 2 alarm notifications; notification by SMS. temperature and vacu
  • VO49H6
    Potential-free contact for combination error message (e.g. supply failure, senso
  • VO49T5
    Premium module: comprises the inert gas inlet, extra connectors for thermoshelve
  • VO49V3
    4 - 20 mA current loop interface (requires option T5); Temperature actual value
  • VO49V6
    4 - 20 mA current loop interface (requires option T5); Temperature of a Pt100 se